RESNET Certified | Measured Airflow, Not Nameplate | Reports Delivered by Email
Stellar Building Performance serves Indiantown, the newest municipality in Martin County, out in the western interior along SR-710 and SR-76.
What Is Mechanical Ventilation Testing?
Florida requires whole house mechanical ventilation in a dwelling unit that tests below 3 air changes per hour at 50 pascals. Mechanical ventilation testing measures the airflow the installed system actually delivers, using a flow hood at the termination point, instead of estimating it from the equipment rating.
We test for Indiantown builders and developers as part of the blower door visit and deliver the report by email, documented against the Florida Energy Conservation Code for the Village of Indiantown Building Division.
Request Indiantown Mechanical Ventilation Testing
we coordinate Indiantown mechanical ventilation testing around your stage of construction, with the report sent by email.
Local Indiantown and Martin County Projects Our Team has Worked On
Florida Energy Code Mechanical Ventilation Requirements
Whole house mechanical ventilation is required whenever a dwelling unit tests below 3 air changes per hour at 50 pascals (R402.4.1.2 and R403.6.1 of the Florida Building Code, Energy Conservation, and M1507.3 of the Florida Building Code, Residential). The trigger is the blower door result, not a design choice, and the building department verifies the ventilation. Homes that do not test below that line are not triggered by this requirement.
Indiantown incorporated at the end of 2017 and is the county’s newest municipality. It runs its own Village of Indiantown Building Division, so permits here do not go through the county.
Indiantown has adopted the 2023 Florida Building Code, 8th Edition, which applies to submittals made on or after January 1, 2024. It is also the most affordable new-construction market in Martin County by a wide margin. Terra Lago by Ryan Homes is building townhomes and single-family homes here at price points well below anything on the coast, which in practice means a small set of repeating plan types built over and over.
That repetition is useful. Once we have tested the first few of a plan type, we know where that plan tends to leak, and the builder can correct it upstream instead of chasing a failing test at CO.
Why is Mechanical Ventilation Testing Beneficial?
Volume builders in Indiantown do not just need a passing number, they need to know which detail moved it.
A ventilation system that underdelivers can cause:
In Indiantown, mechanical ventilation testing turns “it should be fine” into a documented airflow measurement before final inspection. A documented measurement is what keeps the closeout moving.
How We Keep Our Services Simple and Easy
We want completing your Mechanical Ventilation Testing in Indiantown to be as easy as possible.
1.
Schedule your test
You tell us the Indiantown address and when the home will be ready. Once we have tested the first few of a plan type we know where it leaks, so the builder can correct upstream instead of chasing a failure at CO.
2.
onsite measurement
We measure delivered airflow at the ventilation inlet, and at any local exhaust in the scope, with the system running the way it will in service.
3.
Comparison Against the Required Rate
We put the measured airflow next to the rate the dwelling is required to receive, so you get a pass or a specific shortfall instead of a raw reading. If it comes up short, we tell you what is causing it.
4.
Report delivered by email
The report goes out by email to the Indiantown job team, documenting the measured airflow and the required rate for the inspection file.
5.
Ready for Final Inspection approval
With the report on file, the Village of Indiantown Building Division can close out the permit and issue the certificate of occupancy.
Contact Us for Convenient Mechanical Ventilation Testing in Indiantown
Why Builders Choose Stellar Building Performance
Stellar Building Performance
No missed appointments or reschedules.
Confirmed scheduling for Indiantown projects.
We’re on the same team
Other Inspectors
You’re just another sale
Recent Projects in Indiantown and Martin County
Checking in from the field! Ventilation verification usually rides along with our blower door visits, so it shows up in our blower door project updates.
Frequently asked questions about Mechanical Ventilation Testing
The measurement is made during the blower door visit, so it adds a short step to the time already on site in Indiantown. Nothing is drilled, cut or removed.
In Indiantown, whole house mechanical ventilation is required for a dwelling unit that tests below 3 air changes per hour at 50 pascals, and the building department verifies it. That covers new single family homes, duplexes, townhomes and apartment units, plus additions and other conditioned structures that are tested and land below that line.
Common Structures Like:
Additional Structures Like:
Any whole house mechanical ventilation system installed to meet the requirement: a dedicated outdoor air duct with a damper and control, an exhaust only system, a supply system with its own fan, or a balanced system. We measure the airflow actually delivered rather than reading the nameplate.
It can. Where a home tests below 3 air changes per hour, the building department verifies the ventilation, and an undocumented system leaves an incomplete permit file that the Village of Indiantown Building Division will not close out. Having the measurement in hand before final inspection is most of the job.
Ventilation is measured on the finished system, so we schedule it with the blower door visit near the end of the project, once the ventilation equipment is installed and able to run. We provide a pre-inspection, get ready checklist in our proposals so the house is ready for the measurement.
No. Work does not have to stop and the building does not need to be cleared. We just need the ventilation system installed and able to run.
Want the longer version? Read our mechanical ventilation testing overview.
Mechanical Ventilation Testing Code Reference
Whole house mechanical ventilation is required in Indiantown for a dwelling unit that tests below 3 air changes per hour at 50 pascals. R402.4.1.2 of the 2023 Florida Building Code, Energy Conservation, Eighth Edition, carries the blower door test and points to the ventilation requirement, R403.6.1 sets out whole house mechanical ventilation, and M1507.3 of the Florida Building Code, Residential, covers the system itself.
Meeting the requirement does not change the blower door result, which is tested with the ventilation system sealed or shut off. What it changes is whether a result below 3 air changes per hour is allowed to stand on its own.
We keep the full code language on our main page: read the Florida mechanical ventilation code references.
questions? give us a call, this is our specialty!
Need Mechanical Ventilation Testing in Indiantown Before Final Inspection?
Helping Indiantown Builders Stay on Schedule
Coordinated Scheduling
Testing in Indiantown gets scheduled to land before the inspection, not chase it.
accurate results
Measured, not estimated. Calibrated equipment, RESNET certified, documented for the Village of Indiantown Building Division.
reports by email
The report is emailed to everyone on the Indiantown job, not left in a truck.
Other Areas We Serve
Local mechanical ventilation testing in Indiantown, with additional service throughout Brevard County, Indian River County, St. Lucie County, Martin County, and Okeechobee County. Ventilation verification rides along with our blower door testing in Indiantown visit, and we also offer duct leakage testing in Indiantown. Back to mechanical ventilation testing.




